Electric Panel, Single Starter, 1.5 HP

Price: $390.00

Options

Overview

Features

  • Integrated motor starter provides thermal and over current protection of electrical motor
  • Adjustable trip current setting to adjust to specific motor requirements
  • Lockable reset and settings panel for secure operation
  • Lost phase protection to protect motor in the event that the electrical supply looses a leg of power
  • Non metallic corrosion resistant enclosure can be mounted in the equipment room or in the wash bay

Overview

The WashTools Single Starter Electrical Panel is an electrical enclosure containing a motor contactor and overload to be used with various electrical motors

Tech Specs

General
Product Type
Electrical Panel
 
Series
1.5 HP
 
Manufacturer
WashTools
     
Final Installation Dimensions
  Dimensions
15.75" High x 8.75" Wide x 7.00" Depth
 
Weight
8 Lbs
     
Materials, Construction and Finish
  Enclosure Polycarbonate
     
Equipment Mounting Method
  Mount Holes
(4) 3/8" anchor locations per enclosure
  Bolt Configuration (1) top mount and (2) bottom mount locations are 15.00 on center
Panel Details
 
Contactor Type
Telemecanique
  Voltage 208-240 VAC or 460-480 VAC
  Current Range 3.00 to 12.00 A @ 208-240 VAC, 1.25 to 5.00 A @ 460-480 VAC
  Control Voltage 24 VAC or 120 VAC
     
Warranty
 
Manufacturer
WashTools standard limited warranty
     
Shipping
  Parcel # Quantity - Description - Dimensions - Weight (each)
  Parcel #1
(1) - Single Starter Box - 8.00" High x 10.00" Wide x 18.00" Length - 9 Lbs
     

Included

Items Included

  • Electrical Enclosure
  • Integrated self protected motor starter (contactor and overload)
  • Service Pack documentation

Items NOT Included

  • Wall anchors
  • Electrical disconnect(s)
  • High voltage wires
  • Low voltage wires

Installation

The installation of the Single Starter Electric Panel is straight forward. The Service Pack documents that are provided with the product shipment include complete installation and startup instructions.

General
  People Required
1
 
Mechanical Skill Level
Basic - Mounting of enclosure
 
Electrical Skill Level
Advanced - Three phase power and knowledge of local codes is required
 
Pneumatic Skill Level
NA
 
Fluid Skill Level
NA
 
Chemical Knowledge
NA
     
Tools and Equipment Needed
  Unpacking Normal hand tools
 
Erection
Measuring tools needed for positioning and hammer drill for anchors.
 
Assembly
Normal hand tools
 
Wiring
Normal electrical wiring tools
 
Startup
Electrical meter helpful but not required
     
Estimated Timeline
Detail This is the time estimate for installation of the starter panel only. This does not include any other equipment or systems.
Unpacking 10 minutes 
Preparation Assembly  10 minutes 
Enclosure Mounting
30 minutes 
 
Wiring
1 hour
 
Startup & adjustment
30 minutes 
     
Electrical Utility Connections
  Control Box Power Requirements 6 VA @ 24 VAC or .28 A @ 120 VAC
  Control Box Power Connection Type (2) screw terminals
     
Equipment Connections
  Electric Lines  
   Incoming Connection Type and Size High Voltage 3 Conductor + Ground, Low voltage 2 conductor (see local codes for wire size)
  Outgoing Connection Type and Size High Voltage 3 Conductor + Ground (see local codes for wire size)