Booster Pump, +40 PSI, 0.75 HP, Three Phase
Options
| |
|
|
Overview
Features
- Pump capable of providing a 40 PSI+ boost of water line pressure
- Heavy duty cast iron pump housing with bronze impeller
Overview
The WashTools Booster Pump is a pump that can be installed to maintain line pressure in the water line supplying your equipment. This pump typically provides a 40 PSI+ boost to the existing line pressure, but will vary due to the site's line size, existing pressure, flow rate and downstream equipment. Common uses for this pump include feeding pressure fed equipment using a Hydrominder or other equipment that relies on city water pressure to mix and titrate wash solutions. They also are useful in filling high pressure pump tanks during peak usage periods.
Tech Specs
| General |
|
Product Type |
Booster Pump |
| |
Series |
Three Phase Booster Pump |
| |
Manufacturer |
WashTools |
| |
|
|
| Final Installation Dimensions |
| |
Dimensions |
10.00" High x 11.00" Wide x 19.00" Length |
| |
Weight |
48 Lbs |
| |
|
|
| Materials, Construction and Finish |
| |
Pump Body |
Cast Iron |
| |
Impeller |
Bronze |
| |
Feet |
Carbon Steel |
| |
Fasteners |
Stainless Steel |
| |
|
|
| Equipment Mounting Method |
| |
Foot Pads |
(1) cast iron foot pad (6.75" Wide x 3.50" Length x .50" Thick) |
| |
Bolt Configuration |
(2)-3/8" Concrete anchor locations per pad |
|
|
|
| Electrical Motor(s) |
| |
Type |
TEFC |
| |
Quantity |
1 |
| |
Horse Power - Each Motor |
.75 |
| |
Horse Power - Total System |
.75 |
| |
Full Load Amps - Each Motor |
(3.1 A @ 208 VAC), (3.1 A @ 230 VAC), (1.55 A @ 460 VAC) |
| |
Full Load Amps - Total System |
(3.1 A @ 208 VAC), (3.1 A @ 230 VAC), (1.55 A @ 460 VAC) |
| |
Voltage |
3 phase, 208/230/460 VAC @ 60 Hz |
| |
Service Factor |
1.15 |
| |
Environment Rating |
TBD |
| |
Electrical Certifications |
TBD |
| |
Efficiency Rating |
TBD |
|
Electrical Box |
Side mounted with removable cover |
| |
Electrical Entry |
Conduit entry hole |
| |
Wiring Connections |
6 wire leads with grounding lug |
| |
Grounding |
Ground stud in electrical box for connecting ground wire |
| |
Finish |
Painted |
| |
|
|
| Pump Info |
|
Type |
Berkley Centrifugal |
| |
Max Inlet Temperature |
140 F |
| |
Finish |
Painted cast iron |
| |
Impeller |
Single bronze impeller |
| |
Seals |
Carbon/Ceramic, Buna-N |
| |
|
|
| Controller Output Requirements |
| |
Standard |
|
| |
Number 1 |
Pump On |
| |
|
|
| Warranty |
| |
Manufacturer |
WashTools standard limited warranty |
| |
|
|
| Shipping |
| |
Parcel # |
Quantity - Description - Dimensions - Weight (each) |
| |
Parcel #1 |
(1) - Complete Pump Assembly - 12.00" High x 14.00" Wide x 18.00" Length - 49 Lbs |
| |
|
|
Included
Items Included
- Booster pump motor and pump assembly
- Service Pack documentation
Items NOT Included
- Floor anchors and shims
- Wall anchors
- Motor starter(s) and over current protection
- Electrical disconnect(s)
- High voltage wires
Installation
The installation of the Booster Pump is straight forward. The Service Pack documents that are provided with the product shipment include complete installation and startup instructions.
| General |
| |
People Required |
1 Person |
| |
Mechanical Skill Level |
Basic - Mounting of equipment |
| |
Electrical Skill Level |
Advanced - Electrical power and knowledge of local codes is required |
| |
Pneumatic Skill Level |
NA |
| |
Fluid Skill Level |
Basic - Plumbing of pump |
| |
Chemical Knowledge |
NA |
| |
|
|
| Tools and Equipment Needed |
| |
Unpacking |
Normal hand tools |
| |
Erection |
Measuring tools needed for positioning and hammer drill for anchors. |
| |
Assembly |
Normal hand tools |
| |
Wiring |
Normal electrical wiring tools |
| |
Startup |
Electrical meter helpful but not required |
| |
|
|
| Estimated Timeline |
|
Detail |
This is the time estimate for installation of the booster pump only. This does not include any electrical panels, controller wiring or other equipment or systems. |
|
Unpacking |
15 minutes |
|
Preparation Assembly |
15 minutes |
| |
Pump Mounting |
15 minutes |
| |
Motor Wiring |
30 minutes |
| |
Fluid Connections |
1 hour |
| |
Startup & adjustment |
1 hour |
| |
|
|
| Electrical Utility Connections |
|
Pump Power Requirements |
(3.1 A @ 208 VAC), (3.1 A @ 230 VAC), (1.55 A @ 460 VAC) |
|
Pump Power Connection Type |
6 wire leads with grounding lug |
| |
|
|
| Equipment Connections |
|
Liquid Lines |
|
|
Incoming Connection Type and Size |
1 1/4" NPT |
|
Outgoing Connection Type and Size |
1" NPT |
| |
Electric Lines |
|
| |
Incoming Connection Type and Size |
High Voltage 3 Conductor + Ground (see local codes for wire size) |
| |
|
|
All efforts are made to keep these details current but all prices, specifications, availability and terms are subject to change without notice. Taxes, fees, shipping and handling charges are extra and may vary. Valid for United States online purchases through the WashTools site only. WashTools cannot be responsible for pricing or other errors, and reserves the right to cancel orders arising from such errors.
WashTools: BP-3230 Rev 01, JS/ST
|
|
|