Blower System, Legs and 4 Sides
Options
| |
|
|
Overview
Features
- Two sets of side mounted assemblies: removes water from the sides of vehicles with air moving at 130+ miles per hour
- Multiple axis "freedom" design: allows blowers to be raised and lowered, tilted and rotated, slid right and left- to deliver the best custom flow for your operation
- High-performance aluminum blower wheel: moves 4,150 cubic feet of air per minute (tested in AMCA accredited lab)
- Reliable 7.5 HP, TEFC motor: delivers electrical savings and efficiency
- Smooth startup and lower power requirements: remove the need for expensive VFD controls
- Simple, strong and long-lasting aluminum structure
- Corrosion-resistant molded plastic housings with color throughout
- Simple installation, hookup and operation
Overview
The WashTools blower systems have been proven in extreme car wash environments for years. It all begins with a high-performance blower wheel that is coupled to an engineering-matched, high-efficiency motor. This combination generates an air flow comparable to units using twice the horsepower and electricity. The custom-designed plastic housings direct the air to the vehicle surface with a minimum loss of velocity. All important air flow angles and spacings are easily field-adjusted to best fit your operation.
The full range of blower system models can be mixed and matched to provide progressive drying solutions for longer, high- throughput tunnel operations.
Tech Specs
| General |
|
Product Type |
Blower System |
|
Series |
(4) Side Blowers and Legs |
|
Manufacturer |
WashTools |
|
|
|
| Vehicle Clearance |
|
Maximum Height |
NA |
|
Maximum Width |
Adjustable from 114" to 123" |
|
|
|
| Final Installation Dimensions |
|
Dimensions |
108.58" High x 176.00" to 185.00" Wide x 23.80" to 32.07" Length |
|
Proper Airflow |
The blowers must have a minimum of 6" free clearance to the inlet of each blower |
|
Weight |
822 lbs |
|
|
|
| Materials, Construction and Finish |
|
Structural Frame |
Aluminum |
|
Legs |
Aluminum |
|
Feet |
Aluminum |
|
Coatings or Finish |
None |
|
Fasteners |
Stainless Steel |
|
|
|
| Equipment Mounting Method |
|
Foot Pads |
(2) Aluminum fully gusseted foot pads (15.50" Wide x 9.00" Length x .75" Thick) |
|
Bolt Configuration |
(8)-1/2" Concrete anchor locations per pad |
|
|
|
| Blower Wheel |
|
Type |
Backward inclined airfoil blade tuned for 60 hertz operation |
|
Material |
Aluminum |
|
Maximum RPM |
3,600 |
|
Air Volume |
4,150 CFM at housing exit |
|
Air Velocity |
130+ MPH at the outlet |
|
Mounting Method |
Direct connection to motor shaft with taper lock bushing |
|
|
|
| Electrical Motor(s) |
|
Type |
Totally Enclosed Fan Cooled (TEFC) |
|
Quantity |
4 |
|
Horse Power - Each Motor |
7.5 |
|
Horse Power - Total System |
30 |
|
Full Load Amps - Each Motor |
(22.0 @ 208 VAC), (20.6 @ 230 VAC), (10.3 @ 460 VAC) |
|
Full Load Amps - Total System |
(88.0 @ 208 VAC), (82.4 @ 230 VAC), (41.2 @ 460 VAC) |
|
Voltage |
Three phase, 208/230/480 VAC @ 60 Hz |
|
Environment Rating |
IP 54 - Motor is protected from dust and from water splashing onto it from any direction |
|
Electrical Certifications |
UL, cUL, CE |
|
Efficiency Rating |
87.2% |
|
Electrical Box |
Side mounted with removable cover |
|
Electrical Entry |
Threaded conduit entry hole |
|
Wiring Connections |
9 wire leads with 6 terminals |
|
Grounding |
Ground stud in electrical box for connecting ground wire |
|
Finish |
Epoxy paint on cast aluminum |
|
|
|
| Blower Housing(s) |
|
Orientation |
Quantity |
|
Top, Left Hand |
0 |
|
Top, Right Hand |
0 |
|
Side, Left Hand |
2 |
|
Side, Right Hand |
2 |
|
*Left Hand or Right Hand indicates the orientation of the outlet blower nozzle while viewing the blower from the inlet side. Top and Side indicates if the blower is mounted to the top frame (top) or to the dryer leg (side) |
|
|
|
|
Material |
Molded LLDPE (Linear Low Density Polyethylene) |
|
Blower Housing Color |
Red, Black or Blue |
|
Inlet Debris Screen |
Stainless steel |
|
Outlet Safety Screen |
Stainless steel |
|
Outlet Nozzle Shape |
Round |
|
Details |
Universal design for right or left side outlet mounting |
|
|
|
| Sound Info |
|
Maximum dBA |
101 dBA with all blowers on standing directly at the unit |
|
Typical Exit dBA |
84 dBA with exit door open and 30 feet directly past the exit |
|
|
|
| Controller Output Requirements |
|
Standard |
|
|
Number 1 |
Blower motor #1 on |
|
Number 2 |
Blower motor #2 on |
| |
Number 3 |
Blower motor #3 on |
| |
Number 4 |
Blower motor #4 on |
|
Optional |
|
|
N/A |
N/A |
|
|
|
| Warranty |
|
Manufacturer |
WashTools standard limited warranty |
|
|
|
| Shipping |
|
Parcel # |
Quantity - Description - Dimensions - Weight (Each) |
|
Parcel #1 |
(4) - Motor and Fan - 26" High x 28" Wide x 24" Length - 125 Lbs |
|
Parcel #2 |
(4) - Blower Housing - 42.25" High x 28.75" Wide x 13.50" Length - 40 Lbs |
|
Parcel #3 |
(1) - Legs - 17" High x 16" Wide x 110" Length - 162 Lbs |
|
|
|
Included
Items Included
- Aluminum structure and all hardware needed for assembly
- (4) Blower assemblies with fan mounted and balance-tested with motor
- Blower housings with internal safety screens
- Blower inlet cones, debris screens and assembly hardware
- Blower mounting brackets and hardware to mount blower assemblies to the frame
- Floor Anchors
- Service Pack documentation
Items NOT Included
- Floor shims (was Floor anchors and shims)
- Motor starter(s) and over current protection
- Electrical disconnect(s)
- High-voltage wires
Installation
The installation of the blower system is straightforward. The Service Pack documents are provided with the product shipment
| General |
|
People Required |
2 capable of lifting heavy objects |
|
Mechanical Skill Level |
Basic |
|
Electrical Skill Level |
Advanced - Three phase power and knowledge of local codes is required |
|
Pneumatic Skill Level |
NA |
|
Fluid Skill Level |
NA |
|
Chemical Knowledge |
NA |
|
|
|
| Tools and Equipment Needed |
|
Unpacking |
Normal hand tools |
|
Erection |
Ladders required. Forklift would be helpful. Measuring tools needed for positioning and hammer drill for floor anchors |
|
Assembly |
Normal hand tools |
|
Wiring |
Normal electrical wiring tools. |
|
Startup |
Electrical meter helpful but not required |
|
|
|
| Estimated Timeline |
|
Detail |
This is the time estimate for installation of the blower system only. This does not include any electrical panels, controller wiring or other equipment or systems |
|
Unpacking |
30 minutes |
|
Preparation Assembly |
2 hours |
|
Frame Erection |
2 hours |
|
Blower Mounting |
3 hours |
|
Motor Wiring |
3 hours |
|
Startup & adjustment |
3 hours |
|
|
|
| Equipment Connections |
|
Electric Lines |
|
|
Incoming Connection Type and Size |
High Voltage 3 Conductor + Ground (see local codes for wire size) |
|
|
|
All efforts are made to keep these details current but all prices, specifications, availability and terms are subject to change without notice. Taxes, fees, shipping and handling charges are extra and may vary. Valid for United States online purchases through the WashTools site only. WashTools cannot be responsible for pricing or other errors, and reserves the right to cancel orders arising from such errors.